PL18 Series

Key features & specifications

TopologyForward / bridge
Power Range10–80 W forward · 150 W bridge
FamilyPL14 · PL18 · PL58 AC
Rated Powerto 100 W (forward)
Input18–36 or 36–75 Vdc
Footprint18.3 × 19.2 mm max
Frequency200 kHz – 1 MHz
Isolation1750 Vdc basic
Turns4T–8T, integer

PL18 series planar transformers for forward topology, rated to 100 W with an 18–36 or 36–75 Vdc input. A 18.3 × 19.2 mm footprint at 6.5 mm maximum height, with 1750 Vdc basic isolation — the mid-size member of the PL family between PL14 and PL58 AC.

Part number & parameter table

Stresses beyond values listed may cause permanent damage. Functional operation beyond any rating is not implied. All values at T<sub>amb</sub> = 25 °C unless noted.

PL18 — forward topology, rated to 100 W

Part NumberPri TAuxSec. TPri Induct. (mH nom)Ll Induct. (mH nom)Pri DCR (mΩ)Aux DCR (mΩ)Sec. DCR (mΩ)Sch.Max Ht (mm)
PL18.4014T14T (1:1:1:1)350.05123010A16.5
PL18.5015T1—600.051830———
PL18.6016T2—800.082260———
PL18.7017T2—1100.103060———
PL18.8018T2—1500.104060———
PL18.4024T11T & 1T350.0512301.40 || 1.40A26.5
PL18.5025T1—600.051830———
PL18.6026T2—800.082260———
PL18.7027T2—1100.103060———
PL18.8028T2—1500.104060———
PL18.4034T12T & 1T350.0512305.0 || 1.40A36.5
PL18.5035T1—600.051830———
PL18.6036T2—800.082260———
PL18.7037T2—1100.103060———
PL18.8038T2—1500.104060———

Blank cells repeat the value shown on the first row of the group — the group shares its secondary configuration, secondary DCR and schematic.

Document PL18 · Revision A · © 2026 Champs Technologies LLCSimulation & STP files available on request — Contact Us

Mechanical outline & package dimensions

Footprint18.3 × 19.2 mm max
Max HeightH6.5 mm
Isolation1750 Vdc basic
FinishRoHS · Cu leads · Sn/Ag 96/4

Notes